Less Lethal

Quantum Sniffer QS-H150 Portable

Real Time Explosives Trace Detection

Quantum Sniffer Technology

The Quantum Sniffer employs a novel technology for the detection of explosives vapors that is more sensitive than existing detection devices. The advanced technique detects the presence of parts per trillion (ppt) of explosives molecules, without physical contact and in real time. The unique patented vortex sample acquisition system collects the sample, ionizes it with the unique QS™ electro-optical ionization scheme, identifies the sample via standard ion mobility technology and, if an explosive is present, will produce a visual and audible alarm. The LCD will display the identity of the explosive present and the audible alarm can be switched off if required. Quantum Sniffer is the only Explosives Trace Detector with true automatic self calibration — no user intervention is required.

QS-H150

The QS-H150 Portable Explosives Trace Detector was developed in conjunction with the U.S. Navy (NCIS and NAVEODTECHDIV) and PSEAG. The device is capable of detecting trace amounts of most commercial and military explosives, including RDX, PETN, HMX, TNT, Black Powder and Ammonium Nitrate at nanogram level concentrations.
The detection is "real time" with immediate cleardown which dramatically improves throughput. The instrument is noncontact and does not use expensive consumables. The QS-H150 uses a proprietary opto/electrical ionization technique rather than a radioactive source for ionization and hence there is no need to deal with complicated NRC regulatory requirements.

Solutions
  • Aviation and Transportation Security
  • Customs and Border Protection
  • High Threat Infrastructures
  • Cargo and Mail
  • Military
Product Features
  • Novel Ionization Technology, No Radioactive Source
  • True Automatic Continuous Self Calibration
  • Real Time Detection
  • Substance Identification
  • Minimal Maintenance Requirements
  • 8-Hour Battery Operation
  • Easy Downloading of Alarm and Data Files
  • Low Annual Operating Cost
  • Specifications

Detector Type

Ion Mobility Spectrometry (IMS) original, non-radioactive ionization (Patent #6828795)

Sensitivity

Vapors: ppt (parts per trillion)
Particles: pg-ng levels

Selectivity

Less than 1% false positive

Analysis Time

Real Time (1-5 seconds)

Cleardown Time

Immediate

Sample Acquisition

Vapor collection from low levels of contamination via unique patented "tornado" sample acquisition system at a distance of 1/2 to 3" (1 to 8 cm). Particle and large surface collecting via contact wiping.

Warm up Time

15 minutes from "switch-on"

Power

4-hour re-chargeable battery
AC power cord
110/240 VAC, 50/60 Hz12 VDC, vehicle adapter

Signal Processing

Real time analysis
Visual alarm and settable audible alarm

Identifiable Substances

Semtex, C4, RDX, NC, PETN, EGDN, TNT, Dynamite, HMX ANFO, Smokeless Powder, Black Powder, and others via simple sample substance addition. User expandable substance library

Calibration

Continuous automatic self calibration

Dimensions

19.4" L x 5" W x 7.4" H

Weight

12 lbs with 4-hour battery